Work out the water storage a villa, building or site office needs from the number of occupants, the daily use per person and the days of storage, with an optional roof and underground split and a suggested tank plan size. For contractors, QS, plumbers and home owners in Dubai, Sharjah, Abu Dhabi and Ajman.
Worked example
With the calculator’s starting values:
| Number of occupants | 6 |
|---|---|
| Water use per person per day | 250 litres |
| Extra demand per day | 0 litres |
| Days of storage | 1 days |
| Storage | One tank |
| Water depth in the tank | 1.5 m |
| Storage needed | 1,500 litres |
|---|---|
| Storage needed in m³ | 1.5 m³ |
| Storage in UK gallons | 330 UK gal |
| Storage in US gallons | 396 US gal |
| Plan area of the tank at this depth | 1 m² |
| Side of a square tank (inside) | 1 m |
How it is calculated
Daily demand = occupants × litres per person per day + extra demand
Storage = daily demand × days of storage
Roof tank = storage × roof share. Underground tank = storage − roof tank
Plan area = volume (m³) ÷ water depth
Square tank side = √plan area
Allow for freeboard
The plan size is for the water depth you enter. Add the air space above the water, the wall thickness and room for fittings and access when you set the outside size of the tank.
Defaults you can change
250 litres per person per day, 1 day of storage and the 30% roof share are example figures. Use the design basis from your consultant or the requirements that apply to your project.
Water storage in the UAE
Villas and buildings in Dubai, Sharjah, Abu Dhabi and Ajman commonly use an underground tank with a pump to a roof tank, and tank capacities are quoted in litres or gallons. Check whether a gallon figure is UK or US, and size the tanks from the approved plumbing drawings.
Questions
How do I size a water tank for a villa?
Multiply the occupants by the litres per person per day and by the days of storage. With 6 people at the example 250 litres for 1 day, that is 1,500 litres.
What is 1,500 litres in gallons?
About 330 UK gallons or 396 US gallons.
Is the plan size the outside size of the tank?
No. It is the inside water area at the depth you enter. Add freeboard and wall thickness for the outside size.