Drainage Pipe Fall Calculator UAE: Gradient, Fall and Invert Levels

For plumbing contractors, site engineers and home owners in Dubai, Sharjah, Abu Dhabi and Ajman. Enter the pipe run in metres and a gradient as 1 in n, per cent or mm per metre to get the total fall and the invert depth at the end, or enter two invert levels to get the gradient.

Total fall150 mm

Worked example

With the calculator’s starting values:

Inputs
FindFall from a gradient
Pipe run length12 m
Gradient given as1 in n
Gradient, 1 in80
Invert depth at the start0.45 m
Ground fall along the run0 mm
Minimum gradient, 1 in80
Results
Total fall150 mm
Invert depth at the end0.6 m
Gradient1 in 80
Gradient1.25 %
Fall per metre12.5 mm/m
Meets the minimum gradientYes

How it is calculated

Gradient as a fraction = 1 ÷ n, or per cent ÷ 100, or mm per metre ÷ 1,000

Total fall = gradient × pipe run length

Invert depth at the end = depth at the start + total fall − ground fall

From levels: gradient = (start invert level − end invert level) ÷ length, shown as 1 in (1 ÷ gradient)

A 1 in 80 gradient falls 1 m every 80 m, which is 12.5 mm per metre or 1.25%. The invert is the inside bottom of the pipe, so measure levels and depths to the invert, not to the top of the pipe.

Defaults you can change

The 1 in 80 minimum is an example. The right minimum depends on the pipe size, the flow and the rules your design follows, so use the gradient on your drainage drawings. Pipes laid flatter than the design can block, so lay them to the levels shown.

Drainage falls in the UAE

Drainage in Dubai, Sharjah, Abu Dhabi and Ajman is laid to the gradients and invert levels on the approved drainage drawings, and the local authority and consultant set the minimum falls and pipe materials. Gravity drainage is often uPVC, with pipe sizes in mm such as 110 mm and 160 mm, so use the size and gradient shown on your drawings and check levels from the site datum before you dig.

Questions

What does 1 in 80 mean?

The pipe drops 1 unit for every 80 units along its length: 12.5 mm per metre, or 1.25%.

How do I convert per cent to 1 in n?

Divide 100 by the per cent. 2% is 1 in 50, 1% is 1 in 100.

Should I measure to the top or the bottom of the pipe?

To the invert, the inside bottom of the pipe. That is what drainage levels on drawings refer to.