For home owners, tenants and facility managers in the UAE: enter the AC size in TR, its efficiency and the hours it runs, and get the kWh and the AED it adds to your monthly electricity bill.
Worked example
With the calculator’s starting values:
| Cooling capacity per unit | 1.5 TR |
|---|---|
| Number of units | 1 |
| Efficiency (COP) | 3 |
| Hours switched on per day | 10 h |
| Days per month | 30 |
| Compressor running time | 60 % |
| Tariff | DEWA or SEWA slabs |
| Other electricity use this month | 0 kWh |
| Slab 1 rate | 23 fils/kWh |
| Slab 1 up to | 2,000 kWh |
| Slab 2 rate | 28 fils/kWh |
| Slab 2 up to | 4,000 kWh |
| Slab 3 rate | 32 fils/kWh |
| Slab 3 up to | 6,000 kWh |
| Above slab 3 | 38 fils/kWh |
| Fuel surcharge | 6 fils/kWh |
| VAT | 5 % |
| AC running cost per month | 96.38 AED |
|---|---|
| AC electricity per month | 317 kWh |
| Cost per day | 3.21 AED |
| Cost per kWh including surcharge and VAT | 30.45 fils |
How it is calculated
Electrical input (kW) = TR × 3.517 ÷ COP × number of units
kWh per month = kW × hours per day × days × compressor running time %
Slab cost = cost of (other use + AC kWh) − cost of other use alone
Monthly cost = (slab or flat cost + kWh × fuel surcharge) × (1 + VAT)
1 TR is 3.517 kW of cooling. A unit with a COP of 3 draws 1 kW of electricity for every 3 kW of cooling, so a 1.5 TR unit draws about 1.76 kW while the compressor runs.
Defaults you can change
The COP of 3 and the 60% compressor running time are example values. Use the figures from the unit label or the supplier’s data sheet, and your own hours. The slab rates are the DEWA and SEWA residential slabs with a 6 fils/kWh fuel surcharge, rates checked November 2026; DEWA and SEWA publish the tariffs, so confirm them on dewa.gov.ae or sewa.gov.ae or on your latest bill.
Air conditioning costs in the UAE
Air conditioning is the largest part of most summer electricity bills in Dubai, Sharjah, Abu Dhabi and Ajman. Because the residential tariffs are stepped, the same AC unit costs more per kWh in a home that already uses a lot of power, so enter your other monthly use to see which slab the AC falls in. Cleaning filters and keeping the thermostat a little higher are simple ways to cut the running time.
Questions
How much power does a 1.5 ton AC use?
About 1.76 kW while the compressor runs, at a COP of 3. A more efficient unit with a higher COP draws less for the same cooling.
What is COP and EER?
COP is cooling output divided by electrical input, both in kW. EER uses BTU/h per watt, and COP = EER ÷ 3.412.
Does the calculator work for Abu Dhabi?
Choose the flat rate option and enter your own fils/kWh rate from your bill, because the Abu Dhabi tariff is not set up as slabs here.