For architects, MEP designers and contractors in Dubai: choose the building type and enter the number of people, and get the minimum WCs, plus wash basins and showers for labour accommodation and ablution places for a mosque, using the Dubai Building Code ratios.
Worked example
With the calculator’s starting values:
| Building type | Office |
|---|---|
| Number of people | 150 |
| First band of people | 100 |
| People per WC in the first band | 20 |
| People per WC above the first band | 50 |
| WCs needed | 6 WCs |
|---|
How it is calculated
Office: WCs = first 100 people ÷ 20 + people above 100 ÷ 50
Retail: WCs = people ÷ 200
Labour accommodation: 1 WC, 1 wash basin and 1 shower per 10 people
Mosque: 1 WC per 100 worshippers and 1 ablution place per 50
Factory: 1 WC per 25 workers
Each part is rounded up to a whole fixture
The ratios are taken from the Dubai Building Code (Part B) published by Dubai Municipality, rules checked November 2026. Confirm the current edition on the Dubai Municipality website. This is a quick check against the published code; the approving authority and the project consultant have the final say.
What is not covered
Wash basins and urinals for offices, retail and factories, accessible WCs and the split between male and female facilities are not worked out here. Check those against the code and with your consultant.
Sanitary provision in the UAE
The ratios here are Dubai Building Code figures for buildings in Dubai. Sharjah, Abu Dhabi and Ajman have their own building regulations, and labour accommodation may also have to meet separate standards set by the authority that licenses it, so check the rules for your emirate and project.
Questions
How is a part of the ratio counted?
It is rounded up. 101 office staff need 5 WCs for the first 100 and 1 more for the extra person.
Does this include accessible WCs?
No. Add accessible facilities as the code and your consultant require.