For painting contractors, QS and site engineers in the UAE: enter the area in m², the volume solids and the dry film thickness in microns from the specification, and get the litres of paint, packs to buy and the wet film thickness to apply.
Worked example
With the calculator’s starting values:
| Area to paint | 100 m² |
|---|---|
| Number of coats | 2 coats |
| Volume solids | 50 % |
| Dry film thickness per coat | 50 microns |
| Thinner added | 0 % |
| Application loss | 20 % |
| Pack size | 4 L |
| Paint needed | 25 litres |
|---|---|
| Packs to buy | 7 × 4 L |
| Wet film thickness to apply | 100 microns |
| Theoretical spreading rate | 10 m²/L |
| Practical spreading rate | 8 m²/L |
How it is calculated
Theoretical spreading rate (m²/L) = volume solids % × 10 ÷ DFT (microns)
Practical spreading rate = theoretical rate × (1 − application loss)
Paint (litres) = area × coats ÷ practical spreading rate
Wet film thickness = DFT × (100 + thinner %) ÷ volume solids %
One litre of paint spread over 1 m² gives a wet film 1,000 microns thick. Only the solids stay on the surface, so at 50% volume solids that litre leaves 500 microns dry, or 10 m² at 50 microns.
Why the wet film is thicker
Solvent or water in the paint evaporates as it dries, so the film you apply has to be thicker than the dry film in the specification. Check the wet film with a wet film comb as you work, and the dry film with a DFT gauge once it has cured.
Defaults you can change
The 50% volume solids, 50 micron DFT, 20% application loss and 4 L pack are example values. Take the volume solids and DFT from the product data sheet and the coating specification, and set the loss to suit the surface and method: spraying, rough surfaces and wind usually lose more than brushing a smooth wall.
Protective coatings in the UAE
Steelwork, tanks, pipework and concrete on projects in Dubai, Sharjah, Abu Dhabi and Ajman are often painted to a coating specification that sets the system and the dry film thickness of each coat. Heat and sun affect drying and recoat times, so keep to the data sheet limits for the conditions on the day, and check the film thickness as the work goes on.
Questions
What is volume solids?
The share of the paint, by volume, that stays on the surface as dry film. It is printed on the technical data sheet. The higher it is, the more area each litre covers at a given DFT.
Does thinning change the coverage?
Thinning adds volume but no solids, so the paint itself still covers the same area at the same DFT. You need a thicker wet film to reach that DFT. The calculator shows the thinner separately.
Why add an application loss?
The theoretical rate assumes every drop ends up as an even film. Overspray, surface roughness, uneven film and leftovers in the tin mean you use more in practice.