Dry Film Thickness (DFT) Calculator UAE

For painting contractors, QS and site engineers in the UAE: enter the area in m², the volume solids and the dry film thickness in microns from the specification, and get the litres of paint, packs to buy and the wet film thickness to apply.

Paint needed25 litres

Worked example

With the calculator’s starting values:

Inputs
Area to paint100 m²
Number of coats2 coats
Volume solids50 %
Dry film thickness per coat50 microns
Thinner added0 %
Application loss20 %
Pack size4 L
Results
Paint needed25 litres
Packs to buy7 × 4 L
Wet film thickness to apply100 microns
Theoretical spreading rate10 m²/L
Practical spreading rate8 m²/L

How it is calculated

Theoretical spreading rate (m²/L) = volume solids % × 10 ÷ DFT (microns)

Practical spreading rate = theoretical rate × (1 − application loss)

Paint (litres) = area × coats ÷ practical spreading rate

Wet film thickness = DFT × (100 + thinner %) ÷ volume solids %

One litre of paint spread over 1 m² gives a wet film 1,000 microns thick. Only the solids stay on the surface, so at 50% volume solids that litre leaves 500 microns dry, or 10 m² at 50 microns.

Why the wet film is thicker

Solvent or water in the paint evaporates as it dries, so the film you apply has to be thicker than the dry film in the specification. Check the wet film with a wet film comb as you work, and the dry film with a DFT gauge once it has cured.

Defaults you can change

The 50% volume solids, 50 micron DFT, 20% application loss and 4 L pack are example values. Take the volume solids and DFT from the product data sheet and the coating specification, and set the loss to suit the surface and method: spraying, rough surfaces and wind usually lose more than brushing a smooth wall.

Protective coatings in the UAE

Steelwork, tanks, pipework and concrete on projects in Dubai, Sharjah, Abu Dhabi and Ajman are often painted to a coating specification that sets the system and the dry film thickness of each coat. Heat and sun affect drying and recoat times, so keep to the data sheet limits for the conditions on the day, and check the film thickness as the work goes on.

Questions

What is volume solids?

The share of the paint, by volume, that stays on the surface as dry film. It is printed on the technical data sheet. The higher it is, the more area each litre covers at a given DFT.

Does thinning change the coverage?

Thinning adds volume but no solids, so the paint itself still covers the same area at the same DFT. You need a thicker wet film to reach that DFT. The calculator shows the thinner separately.

Why add an application loss?

The theoretical rate assumes every drop ends up as an even film. Overspray, surface roughness, uneven film and leftovers in the tin mean you use more in practice.