For contractors and villa owners in the UAE: enter the roof area in m² and the design rainfall intensity, and get the rainwater flow in L/s, the number of downpipes and a check on the gutter.
Worked example
With the calculator’s starting values:
| Roof area draining to the gutters | 150 m² |
|---|---|
| Runoff coefficient | 1 |
| Design rainfall intensity | 50 mm/h |
| Capacity of one downpipe | 6 L/s |
| Gutter capacity per outlet | 0 L/s |
| Downpipes needed | 1 nr |
|---|---|
| Rainwater flow | 2.08 L/s |
| Flow per downpipe | 2.08 L/s |
| Roof area per downpipe | 150 m² |
How it is calculated
Rainwater flow Q (L/s) = C × i × A ÷ 3,600
i = rainfall intensity in mm/h, A = roof area in m², C = runoff coefficient
Downpipes = Q ÷ capacity of one downpipe, rounded up
Gutter check: Q ÷ number of outlets compared with gutter capacity per outlet
One millimetre of rain on one square metre is one litre, which is why mm/h × m² gives litres per hour, and dividing by 3,600 gives litres per second.
Defaults you can change
The 50 mm/h rainfall and 6 L/s downpipe capacity are examples to show the method, not design values. Downpipe and gutter capacities depend on size, shape, outlet and fall, so take them from the manufacturer’s tables or the drainage design. For a pitched roof, ask your designer whether to add an allowance for wind-driven rain on the roof slope.
Roof drainage in the UAE
Rain is infrequent in Dubai, Sharjah, Abu Dhabi and Ajman, but storms can drop a lot of water in a short time, as the April 2024 floods showed, so blocked or undersized outlets quickly flood roofs and balconies. Keep at least two outlets on each roof area where you can, keep them clear of sand, and follow the drainage design approved for the building.
Questions
Why use more than one downpipe if one is enough?
If a single outlet blocks with sand or debris, the roof has no way to drain. A second outlet or an overflow gives a safety margin.
Does a pitched roof need a different area?
The plan area is the usual starting point. Some design guides add part of the sloping area for wind-driven rain; follow your designer.