For home owners, designers and contractors in Dubai: enter a room’s clear length and width in metres, choose the room type, and check the net area in m² and the shortest side against the minimum room sizes in Dubai Building Code Table B.3.
Worked example
With the calculator’s starting values:
| Room type | Bedroom or living room |
|---|---|
| Room length (clear) | 3.5 m |
| Room width (clear) | 3.2 m |
| Net area if not rectangular | 0 m² |
| Minimum area, bedroom or living room | 10.5 m² |
| Minimum dimension, bedroom or living room | 3 m |
| Result | Meets the minimum |
|---|---|
| Net room area | 11.2 m² |
| Minimum area required | 10.5 m² |
| Shortest side | 3.2 m |
| Minimum dimension required | 3 m |
How it is calculated
Net area = length × width (or the net area you enter for an irregular room)
Shortest side = the smaller of length and width
Meets the minimum when net area ≥ minimum area and shortest side ≥ minimum dimension
The limits used
The starting limits come from Table B.3, Minimum room sizes, in the Dubai Building Code 2021 edition, published by Dubai Municipality (checked November 2026): bedroom or living room 10.5 m² with a 3 m minimum dimension; studio, including the bathroom and kitchen space, 21 m² and 3 m; enclosed kitchen 5.4 m² and 1.8 m; housekeeper’s or guard room 4.5 m² and 2.1 m. Every limit is an input, so you can update it if the code changes. Confirm the current edition on the Dubai Municipality website.
The code also asks for at least 1.2 m of clear space between kitchen counters. Bathrooms have no area limit in the table; they must meet the fixture clearances in the code instead.
This is a quick check against the published code. The approving authority and your project consultant have the final say.
Room sizes in the UAE
The Dubai Building Code applies to buildings in Dubai, and its minimum room sizes are checked when drawings are submitted for a permit, so it is worth checking them early in the layout. Sharjah, Abu Dhabi and Ajman have their own building regulations, so for projects there use this page only as a guide and check the local municipality’s rules.
Questions
Does the 3 m minimum apply to both sides of a bedroom?
Yes. Table B.3 gives the minimum dimension as the length and width of the room, so both must be at least 3 m for a bedroom or living room.
Is an open kitchen checked the same way?
Table B.3 only lists an enclosed kitchen (5.4 m² and 1.8 m). An open kitchen is part of the living space, so check the combined room instead.
Do these sizes apply in Sharjah or Abu Dhabi?
No. Table B.3 is part of the Dubai Building Code. Other emirates set their own requirements.