For villa owners, building owners and installers in the UAE: enter your yearly electricity use in kWh from your bills, the peak sun hours and performance ratio for your site, and the panel rating in watts, and get the system size in kWp, the number of panels and the roof area they need.
Worked example
With the calculator’s starting values:
| Yearly electricity use | 12,000 kWh |
|---|---|
| Share to cover with solar | 100 % |
| Peak sun hours | 5.5 h per day |
| Performance ratio | 80 % |
| Panel rating | 550 W |
| Panel area | 2.6 m² |
| System size needed | 7.47 kWp |
|---|---|
| Panels | 14 panels of 550 W |
| Installed size | 7.7 kWp |
| Panel area (without walkways) | 36.4 m² |
| Expected yearly output | 12,366 kWh |
How it is calculated
Yield per kWp = peak sun hours × 365 × performance ratio
System size (kWp) = yearly kWh to cover ÷ yield per kWp
Panels = system size × 1,000 ÷ panel watts, rounded up
Expected output = installed kWp × yield per kWp
Defaults you can change
The 5.5 peak sun hours, 80% performance ratio, 550 W panel and 2.6 m² panel area are example values. Use the peak sun hours for your location from your installer or a solar resource map, and the panel size and rating from the data sheet. The panel area does not include walkways, edge distances or spacing between rows, so the roof area you need will be larger.
Rooftop solar in the UAE
In Dubai, DEWA’s Shams Dubai programme lets building owners connect rooftop solar to the grid, with an approved contractor doing the installation. In Sharjah, Abu Dhabi and Ajman, check the connection rules with your utility (SEWA, ADDC or Etihad Water and Electricity) before you size the system. Dust builds up quickly on UAE roofs, so plan for regular panel cleaning.
Questions
Where do I find my yearly kWh?
Add up the consumption on your last 12 electricity bills. Summer months are much higher than winter, so use a full year.
Can I cover 100% of my use?
Only if the roof has enough clear area. Lower the share to cover until the panel area fits your roof.