For contractors, QS and home owners in Dubai, Sharjah, Abu Dhabi and Ajman. Enter the footing size and number, and get the footing concrete, the blinding concrete under it, and the totals in m³ and cft.
Worked example
With the calculator’s starting values:
| Length | 1.8 m |
|---|---|
| Width | 1.8 m |
| Depth | 600 mm |
| Number of footings | 8 |
| Blinding thickness | 50 mm |
| Blinding projection each side | 100 mm |
| Wastage allowance | 5 % |
| Footing concrete to order | 16.33 m³ |
|---|---|
| Blinding concrete to order | 1.68 m³ |
| Footing concrete in cft | 576.7 cft |
How it is calculated
Footing = length × width × depth × number
Blinding = (length + 2 × projection) × (width + 2 × projection) × thickness × number
To order = net volume × (1 + wastage)
Blinding (also called PCC or lean concrete) is a thin layer under the footing that gives a clean, level base. Footing and blinding are usually different mixes, so they are shown separately.
Footings in the UAE
Villas and low-rise buildings in Dubai, Sharjah, Abu Dhabi and Ajman often sit on isolated or combined pad footings, sized by the structural engineer from the soil investigation. Below-ground concrete often needs protection such as waterproofing or a coating, and a sulphate-resisting mix where the specification calls for one, so check your drawings and specification.
Questions
Does this work for stepped footings?
Work out each step as its own rectangle, then add the results.
Where do I find the blinding thickness?
On the foundation details. 50 mm is only an example.