For engineers, QS and contractors in Dubai, Sharjah, Abu Dhabi and Ajman. Enter the slab thickness, screed and allowances for finishes and ceilings, and get the dead load in kN/m² and kg/m², and the total over an area.
Worked example
With the calculator’s starting values:
| Slab thickness | 200 mm |
|---|---|
| Reinforced concrete unit weight | 25 kN/m³ |
| Screed thickness | 50 mm |
| Screed unit weight | 22 kN/m³ |
| Floor finishes | 1 kN/m² |
| Ceiling and services | 0.5 kN/m² |
| Slab area | 100 m² |
| Total dead load | 7.6 kN/m² |
|---|---|
| In kilograms per m² | 775 kg/m² |
| Total over the area | 760 kN |
| Total over the area | 77.5 tonnes |
How it is calculated
Self-weight = thickness (m) × unit weight (kN/m³)
Screed = screed thickness (m) × screed unit weight
Total = self-weight + screed + finishes + ceiling and services
kg/m² = kN/m² × 1,000 ÷ 9.81
A 200 mm slab at 25 kN/m³ weighs 5.0 kN/m², or about 510 kg/m². The screed, finishes and ceiling figures are examples; take them from your design basis or the product data.
Using this in the UAE
Engineers in Dubai, Sharjah, Abu Dhabi and Ajman work to the codes named in the project’s design basis and the local authority’s requirements. Use this calculator for quick checks and estimates; the design loads, including imposed loads and partitions, come from the structural engineer.
Questions
Does this include live load?
No. It covers permanent (dead) loads only. Imposed loads depend on the use of the floor and are set by the design code.
Why 25 kN/m³ and not 24?
24 kN/m³ is for plain normal-weight concrete; reinforced concrete is usually taken as 25 kN/m³ to allow for the steel.