For contractors, steel fixers and QS in Dubai, Sharjah, Abu Dhabi and Ajman. Enter the tonnage of reinforcement and the wire used per tonne, and get the binding wire in kilograms and coils.
Worked example
With the calculator’s starting values:
| Reinforcement | 25 tonnes |
|---|---|
| Binding wire per tonne of steel | 8 kg/t |
| Coil weight | 20 kg |
| Wastage | 5 % |
| Binding wire | 210 kg |
|---|---|
| Coils | 11 coils |
How it is calculated
Binding wire (kg) = steel (t) × wire per tonne × (1 + wastage)
Coils = binding wire ÷ coil weight, rounded up
Small bars at close spacing have many more intersections per tonne than large bars, so they use more wire. The 8 kg per tonne default is an example only; track your own usage on a few pours and use that figure.
Binding wire in the UAE
Annealed binding wire is sold by the coil at building materials shops across Dubai, Sharjah, Abu Dhabi and Ajman, and coil weights vary by brand, so enter the weight printed on the coil you buy. Get the steel tonnage from the bar bending schedule or the slab rebar calculator.
Questions
Can I count wire by intersections instead?
Yes, if you know the number of ties and the wire length per tie. This calculator uses the per-tonne method because it is quicker for estimating.
Is binding wire included in the rebar weight?
No. It is ordered separately.