Rockwool vs Glasswool Insulation in the UAE: Densities (24 to 100 kg/m³), BS EN 13162 Fire Class A1 Rules & Partition Quantities

Interior under fit-out with new drywall partitions and a dust-covered floor

Nothing triggers an acoustic or Civil Defence snag on a commercial fit-out in Dubai, Sharjah, or Ajman faster than closing up the second side of a gypsum stud wall after stuffing the cavity with cheap 16 kg/m³ blanket glasswool rolls instead of the 50 mm × 60 kg/m³ semi-rigid Rockwool slabs called out on the approved shop drawings. Within months, low-density roll blankets sag under their own weight in vertical stud bays—leaving the top 300 mm of the wall completely hollow so voices carry clear across clinic or office rooms—and fail the consultant’s 1-hour or 2-hour fire-resistance inspection.

In the UAE, mineral wool thermal and acoustic insulation for partitions, roofs, and facades is specified to BS EN 13162:2012+A1:2015 (Factory made mineral wool MW products — Specification), ASTM C612-25 (Standard Specification for Mineral Fiber Block and Board Thermal Insulation), and non-combustible reaction-to-fire testing under BS EN 13501-1:2018 (Euroclass A1). This guide compares Rockwool (stone wool) and Glasswool (fiberglass) across densities from 24 kg/m³ to 100 kg/m³, explains where each belongs on a UAE site, and walks through exact 1200×600 mm slab pack quantities.

Quick-Answer Cheat Sheet: Choosing Rockwool vs Glasswool by Density

If you are pricing a fit-out BOQ or ordering mineral wool packs for immediate site delivery in Sharjah, Dubai, or Ajman, use these standard UAE density and packaging rules:

  • 16 to 24 kg/m³ Glasswool Blanket Rolls (50 mm Thick): Supplied in compressed rolls (typically 1.20 m × 10 m or 1.20 m × 15 m = 12 m² to 18 m² per roll, plain or FSK foil-faced). Used for horizontal false-ceiling acoustic overlays, warehouse sandwich-panel roof insulation, and light non-fire-rated office partitions where mechanical Retaining Pins or friction fit hold the blanket.
  • 40 to 50 kg/m³ Semi-Rigid Rockwool Slabs (50 mm or 75 mm Thick): Supplied in 1200 mm × 600 mm flat boards (0.72 m² per slab)—sized to friction-fit snugly inside standard 600 mm c/c metal C-studs without sagging. The standard UAE choice for internal bedroom, office, and corridor gypsum partitions requiring STC 45–50 dB sound reduction.
  • 60 to 80 kg/m³ High-Density Rockwool Slabs (50 mm, 75 mm, or 100 mm Thick): Supplied in 1200 mm × 600 mm boards. Mandatory for 1-hour and 2-hour fire-rated gypsum partitions, hotel/clinic/classroom acoustic walls (STC 52–58 dB), double-leaf blockwork cavity walls, and plant-room enclosures.
  • 100 to 140 kg/m³ Rigid Rockwool Fire-Stop & Facade Slabs: High-compression stone wool boards used for UAE Civil Defence exterior ventilated facade cavities, curtain-wall perimeter slab-edge fire barriers, and industrial high-temperature duct/pipe insulation.
  • Standard UAE Slab Pack Coverage: Because each 1200×600 mm board covers 0.72 m², a standard 6-slab pack of 50 mm Rockwool covers 4.32 m² (and an 8-slab pack covers 5.76 m²; for 75 mm or 100 mm thickness, packs typically hold 4 slabs = 2.88 m² per pack).

Rockwool (Stone Wool) vs Glasswool: Fire Rating, STC Acoustics & Specs

Although both Rockwool and Glasswool are classified as mineral wools under BS EN 13162:2012+A1:2015 and achieve a thermal conductivity (λ) between 0.033 and 0.038 W/m·K, they are spun from different raw materials and perform very differently in a building fire or high-decibel acoustic wall.

Rockwool (Stone Wool) is spun from molten basalt volcanic rock and diabase at around 1,500°C. Its fibers have a dense, non-directional structure that resists temperatures above 1,000°C without melting or losing dimensional stability—making it the benchmark Euroclass A1 fire-stopping core under BS EN 13501-1:2018 and ASTM C612-25. That higher mass per cubic metre (40 to 100+ kg/m³) also damps low-frequency mechanical hum and speech far more effectively than lightweight blankets.

Glasswool (Fiberglass) is spun from molten silica sand and recycled glass cullet into long, flexible, resilient fibers. While unfaced glasswool also achieves Euroclass A1 non-combustibility, its glass fibers begin to soften and sinter around 350°C to 500°C. It excels where lightweight thermal efficiency, fast roll coverage over large areas, and compression recovery are priorities—such as above perforated metal ceiling tiles or under corrugated GI roof sheets.

Technical ParameterGlasswool Blanket Roll (16–24 kg/m³)Glasswool Partition Batt (32–48 kg/m³)Rockwool Cavity Slab (40–60 kg/m³)Rockwool Fire/Facade Slab (80–100 kg/m³)
Governing StandardBS EN 13162 / ASTM C553BS EN 13162 / ASTM C612BS EN 13162 / ASTM C612BS EN 13162 / ASTM C612
Fire Classification & Melt TempEN 13501-1 Class A1 (Unfaced); ~350–450°C limitEN 13501-1 Class A1; ~450–500°C limitEN 13501-1 Class A1; >1,000°C melting pointEN 13501-1 Class A1; >1,000°C fire barrier
Standard UAE Dimensions1.20 m × 10 m or 15 m roll (12–18 m²)1200 × 600 mm slab (0.72 m²/board)1200 × 600 mm slab (0.72 m²/board)1200 × 600 mm slab (0.72 m²/board)
Common UAE Thicknesses50 mm, 75 mm, 100 mm50 mm, 75 mm50 mm, 75 mm, 100 mm50 mm, 75 mm, 100 mm
Thermal Conductivity (λ)0.036 – 0.040 W/m·K0.033 – 0.036 W/m·K0.034 – 0.036 W/m·K0.035 – 0.037 W/m·K
Best UAE Site ApplicationFalse ceilings, metal roofs & HVAC wrapsStandard non-fire office drywall cavitiesFire-rated drywall, hotels, clinics & block cavitiesCurtain-wall fire-stops, facades & plant rooms

UAE Drywall Inspection Warning: Never Stuff a 75 mm Slab into a 50 mm C-Stud Cavity

Some site supervisors assume that squeezing a 75 mm thick Rockwool slab inside a 50 mm metal stud frame gives “extra insulation.” In reality, compressing mineral wool crushes the dead-air pockets that provide thermal resistance, transfers structural vibration directly from one gypsum leaf to the other, and bows the 12.5 mm gypsum board outward between screw lines. Always match a 50 mm slab inside a 50 mm or 70/75 mm C-stud (or a 75 mm slab inside a 75 mm or 100 mm C-stud) from our Gypsum & Ceilings range.

Metal C-stud gypsum board partition frame ready for 1200x600 mm Rockwool acoustic and fire insulation slabs in the UAE
Standard UAE metal C-studs spaced at 600 mm centres accept 1200×600 mm semi-rigid Rockwool or Glasswool partition slabs with a tight friction fit and zero vertical slumping.

Worked UAE Partition Take-Off: 1200×600 mm Slabs, Packs & Acoustic Sealant

When estimating cavity insulation for a drywall package in Sharjah or Dubai, always calculate your metal framing and gypsum board counts first using our Gypsum Partition Calculator. Because insulation only fills a single central layer inside the stud cavity (whereas gypsum boards are installed on both sides, often in double layers), your net insulation area equals 1× the net single-side wall area plus a 5% cutting allowance.

Worked Quantity Example: 42-Metre Clinic / Office Acoustic & Fire-Rated Partition Package

Project Scope: Building 42.0 linear metres of full-height (3.20 m slab-to-slab) 1-hour fire-rated acoustic partitions using 75 mm GI studs at 600 mm centres, double-layer 12.5 mm fire-rated gypsum boards on each side, and 50 mm thick × 60 kg/m³ Rockwool slabs, with 6 × 0.90 m × 2.10 m door openings.

  1. Step 1 — Calculate Net Wall Cavity Area:
    • Gross partition area = 42.0 m × 3.20 m = 134.40 m².
    • Deduct 6 door openings = 6 × (0.90 m × 2.10 m) = 11.34 m².
    • Net insulated cavity area = 134.40 − 11.34 = 123.06 m².
  2. Step 2 — Convert Net Area into 1200×600 mm Rockwool Slabs & 6-Slab Packs:
    • Add 5% site trimming wastage (around MEP backboxes and top/bottom tracks) = 123.06 m² × 1.05 = 129.21 m² gross.
    • Area of one 1200 mm × 600 mm Rockwool slab = 1.20 m × 0.60 m = 0.72 m² per slab.
    • Total slabs required = 129.21 ÷ 0.72 = 179.46 → 180 Slabs.
    • Standard UAE 50 mm × 60 kg/m³ Rockwool pack (6 slabs/pack = 4.32 m² per pack): 180 ÷ 6 = Order 30 Packs of 50 mm × 60 kg/m³ Rockwool Slabs (129.60 m² total). (Note: If ordering 8-slab packs at 5.76 m²/pack, order 23 packs.)
  3. Step 3 — Add Perimeter Acoustic & Intumescent Fire Sealant + Track Tape:
    • Even 60 kg/m³ Rockwool loses 10–15 dB of sound isolation if the 5 mm gap under the floor U-track and ceiling U-track is left unsealed.
    • Total perimeter track length = 42.0 m × 2 (top & bottom) = 84.0 linear metres of U-track → Order 3 rolls of 70 mm × 30 m PE Acoustic Isolation Foam Tape.
    • Dual-side acoustic/intumescent acrylic sealant beads along top, bottom, and wall-abutment edges (~180 linear metres at ~10 m per 310 ml cartridge) → Order 18 × 310 ml Cartridges of Fire/Acoustic Acrylic Sealant.

Tip: Check your skim-coat and wall paint quantities for the finished drywall with our Paint Calculator and compute 5% VAT on your order using our UAE VAT Calculator.

5 Common Mistakes on UAE Sites (And How to Avoid Them)

  1. Stopping the Insulated Partition at False-Ceiling Level (2.70 m) Instead of Slab Soffit: If you stop a bedroom, clinic, or meeting-room partition at the 600×600 mm suspended ceiling grid and leave the 500 mm plenum above open, sound bounces straight over the top of the wall through the ceiling tiles. Always run acoustic and fire-rated partitions full height to the concrete slab soffit—or install a 50 mm Rockwool plenum barrier above the ceiling line.
  2. Leaving Uninsulated Gaps Around Electrical Conduit Drops & Socket Boxes: Back-to-back BS 1363 electrical socket boxes cut into opposite sides of a drywall partition act like an open megaphone through the wall. Offset socket boxes into adjacent stud bays (at least 300–600 mm apart), wrap the back of the GI knock-out box with acoustic putty or mineral wool, and seal perimeter joints with acrylic sealant from our Adhesives & Sealants department.
  3. Using Low-Density (16–24 kg/m³) Roll Blankets Vertically Without Mechanical Retention: Unpinned lightweight glasswool blankets slump downward inside tall vertical stud walls over time, especially when building vibration or HVAC pressure differentials shake the partition. In vertical walls over 2.4 m high, always use semi-rigid 40 to 80 kg/m³ Rockwool or Glasswool partition slabs (1200×600 mm) that friction-lock between the 600 mm C-stud flanges, or secure tall cavity insulation with self-adhesive steel spindle pins.
  4. Cutting Rockwool Slabs with a Dull Blade (Tearing Rather Than Slicing): Tearing mineral wool by hand leaves ragged 20–30 mm gaps along the stud flanges that leak both sound and heat. Cut slabs 5 mm wider than the clear stud spacing on a flat board using a long serrated insulation knife or heavy-duty snap-off utility knife from our Hand Tools range against a straightedge.
  5. Handling Mineral Wool on Site Without FFP2 Dust Masks, Goggles & Gloves: Cutting Rockwool and Glasswool in enclosed UAE rooms before the AC is commissioned releases airborne mineral fibers that irritate skin, eyes, and lungs. Equip every installer with EN 166 safety goggles, FFP2 dust respirators, and coated work gloves from our Safety & PPE category.
Fire-rated gypsum board drywall installation over Rockwool cavity insulation in a UAE commercial fit-out
Combining 50 mm to 75 mm high-density Rockwool cavity slabs (BS EN 13162 Class A1) with fire-rated gypsum boards and intumescent perimeter sealant delivers certified 1-hour and 2-hour fire partitions across UAE projects.

Frequently Asked Questions (FAQs)

Which is better for gypsum partition soundproofing in the UAE: Rockwool or Glasswool?

For vertical drywall partitions in offices, hotels, clinics, and villas, semi-rigid Rockwool slabs (40 to 80 kg/m³ density) outperform standard 16–24 kg/m³ glasswool rolls because their higher mass and dense, multi-directional basalt fiber structure absorb low- and mid-frequency noise (achieving STC 48 to 58 dB depending on board layers) and never slump down inside the stud cavity.

How many square metres are in one pack of 50 mm Rockwool slabs in the UAE?

Standard UAE Rockwool partition slabs measure 1200 mm × 600 mm (0.72 m² per board). A standard 6-slab pack of 50 mm Rockwool covers 4.32 m², while an 8-slab pack (common in 40–50 kg/m³ grades) covers 5.76 m². For 75 mm and 100 mm thicknesses, packs typically contain 4 slabs (2.88 m² per pack).

What density of Rockwool is required for fire-rated gypsum partitions in the UAE?

Most tested 60-minute and 120-minute fire-rated gypsum drywall systems approved by UAE Civil Defence specify 50 mm to 75 mm thick Rockwool slabs at 50 kg/m³, 60 kg/m³, or 80 kg/m³ density (Euroclass A1 non-combustible under BS EN 13501-1:2018), paired with double-layer 12.5 mm or 15 mm fire-rated (Type F) gypsum boards.

What drives the price of Rockwool slabs and Glasswool rolls in the UAE?

The price per pack or roll in AED (+ 5% VAT) is determined by four factors: density in kg/m³ (a 60 kg/m³ or 80 kg/m³ slab contains significantly more mineral fiber by weight than a 24 kg/m³ roll or 40 kg/m³ slab), thickness (25 mm, 50 mm, 75 mm, or 100 mm), facing type (unfaced plain board versus FSK aluminum foil vapour-barrier facing or black glass-tissue facing), and full truckload/pallet volume delivered to site.

Need Rockwool Slabs, Glasswool Rolls, Gypsum Boards & Metal Framing on Site?

Al Tashteb Al Saree Building Materials Trading (Bu Tina, Sharjah) supplies 1200×600 mm Rockwool acoustic and fire-rated slabs (40 to 100 kg/m³), foil-faced and plain Glasswool rolls, regular/MR/fire-rated gypsum boards, GI C-studs and U-tracks, acoustic sealants, and site Hand Tools across Sharjah, Ajman, and Dubai. Browse our Gypsum & Ceilings, Adhesives & Sealants, and Safety & PPE categories or send us your partition BOQ on WhatsApp for a fast quote in AED including 5% VAT.