Terraco EIFS Perma (Mineral Wool) System

Mineral wool system for higher fire ratings. Supplied by Al Tashteb Al Saree, authorised Terraco distributor in Sharjah and Dubai.

SKU: ATS-TER-H1376 Category:
Request a quote
Please enable JavaScript in your browser to complete this form.
Tell us the quantity needed, or the area to be covered.
Brand, size, colour or other details that help us prepare your quote.

Terraco EIFS Perma (Mineral Wool) System is Terraco’s external insulation and finish system built on mineral wool (MW) boards, recommended when a higher fire rating is required or the wall needs to breathe. Al Tashteb Al Saree is an authorised Terraco distributor, supplying EIFS Perma components from our shop in Bu-Tina, Sharjah, to Dubai, Sharjah, Ajman and the rest of the UAE.

Ask for a system quote on WhatsApp or call +971 52 510 4678.

What is EIFS Perma?

Perma uses mineral wool instead of polystyrene as the insulation layer. Terraco recommends it where a higher fire rating is required, and for old or moisture-prone buildings where wall breathability matters. Because mineral wool is vapour-open, the whole system uses breathable layers: a silicate primer and a breathable finish.

System build-up

  1. Adhesive: Styrofix
  2. Insulation: mineral wool boards, thickness chosen for the required U-value
  3. Mechanical fixing: dedicated fasteners for mineral wool boards
  4. Basecoat: Styrobond DP with Terramesh glass-fibre mesh, 3–5 mm overall
  5. Primer: Terraco Silprime
  6. Finish: breathable finish only: Terracoat Sil or Terol mineral render

Thermal performance

Mineral wool thicknessU-value
100 mm0.40 W/(m²·K)
150 mm0.27 W/(m²·K)

Mineral wool has a thermal conductivity of 0.040 W/(m·K), higher than EPS or XPS, so it needs a thicker board for the same U-value. Values are indicative; your consultant should confirm the thickness for the project.

Fire safety

Terraco recommends Perma when a higher fire rating is required, but its brochure does not state a specific rating. In the UAE, facade systems must meet the UAE Fire and Life Safety Code, so confirm the classification and test evidence with your consultant and Civil Defence before ordering.

Guarantee and approvals

The system is covered by the Terraco International Guarantee when it is finished with Terracoat Sil or Terol and installed by an Approved Terraco EIFS Applicator. Terraco lists approvals for its EIFS range including EOTA ETAG 004, BBA, NSAI and UAE approvals.

Where to use it

  • Buildings where the specification calls for non-combustible insulation or a higher fire rating
  • Older or moisture-prone buildings where the wall needs to breathe

Frequently asked questions

Why can’t I use any finish on Perma?

Mineral wool is vapour-open, so Terraco limits the finish to breathable coatings (Terracoat Sil or Terol) to keep the system breathable and under guarantee.

How does Perma compare with Alpha and Polar?

Alpha (EPS) is the general-purpose system and Polar (XPS) suits hot, humid, air-conditioned buildings. Perma trades a thicker board for fire performance and breathability.

Perma vs Alpha vs Polar at a glance

PermaAlphaPolar
InsulationMineral woolEPS / graphite G-EPSXPS
Thermal conductivity0.040 W/(m·K)0.033 / 0.030 W/(m·K)0.030 W/(m·K)
U-value at 100 mm0.40 W/(m²·K)0.33 / 0.30 W/(m²·K)0.30 W/(m²·K)
PrimerSilprimeP PrimerP Primer
FinishesBreathable only: Terracoat Sil or TerolTerracoat, Terralite, TerolTerracoat, Terralite, Terol
Best forHigher fire rating, breathable wallsGeneral new build and renovationHot, humid, air-conditioned buildings

Figures are from the Terraco EIFS brochure and are indicative.

Choosing board thickness

Because mineral wool insulates slightly less per millimetre than polystyrene, Perma needs a thicker board for the same U-value: about 150 mm gives 0.27 W/(m²·K), while 100 mm gives 0.40. Thicker boards mean deeper window reveals and longer fixings, so agree the target U-value with your consultant early and check it against Dubai Green Building Regulations or Estidama requirements where they apply.

Good practice on site

  • Use only the dedicated mechanical fasteners for mineral wool; it needs more positive fixing than EPS.
  • Keep boards dry in storage and on the wall until the basecoat is on; wet mineral wool loses performance.
  • Embed Terramesh fully in Styrobond DP at 3–5 mm overall, with mesh overlaps at joints and diagonal patches at window and door corners.
  • Use only Silprime and a breathable finish so the system stays vapour-open and under the Terraco guarantee.
  • Installation by an Approved Terraco EIFS Applicator is a condition of the Terraco International Guarantee.

What to send us for a quote

Send elevations or total wall area, the required U-value or board thickness, the finish and colour you want, and the project location. We’ll put together the full Perma component list with Terraco: adhesive, boards, fixings, basecoat, mesh, primer and finish.

Data sheets and related products

System details from the Terraco EIFS brochure. Always check the latest Terraco documentation before specifying.

Reviews