Terraco EIFS Alpha (EPS) System is Terraco’s external insulation and finish system built on expanded polystyrene (EPS) or graphite-enhanced G-EPS boards. Terraco describes it as its best-selling EIFS system, used for new build and renovation. Al Tashteb Al Saree is an authorised Terraco distributor, supplying EIFS Alpha components from our shop in Bu-Tina, Sharjah, to Dubai, Sharjah, Ajman and the rest of the UAE.
Ask for a system quote on WhatsApp or call +971 52 510 4678.
What is EIFS Alpha?
An EIFS (exterior insulation and finish system) wraps the outside of a building in insulation boards, then covers them with a mesh-reinforced basecoat and a decorative finish. Insulating the outside of the wall keeps the sun’s heat out of the structure, which matters in the UAE, where most of a building’s energy goes on air-conditioning. Alpha is the EPS version of Terraco’s system. With G-EPS boards, Terraco states about 10% more thermal efficiency than standard EPS.
System build-up
- Adhesive: Styrofix, at 4–5 kg/m² (spot or notched trowel) or 5–6 kg/m² (ribbon and dab)
- Insulation: EPS or G-EPS boards, standard size 600 × 1200 mm, thickness chosen for the required U-value
- Mechanical fixing: plastic fasteners with plastic or steel pin dowels
- Basecoat: Styrobond DP with Terramesh glass-fibre mesh, 3–5 mm overall
- Primer: Terraco P Primer
- Finish: Terracoat, Terralite or Terol decorative coating
Thermal performance
| Board | Thermal conductivity (K) | U-value at 100 mm |
|---|---|---|
| EPS | 0.033 W/(m·K) | 0.33 W/(m²·K) |
| G-EPS (graphite) | 0.030 W/(m·K) | 0.30 W/(m²·K) |
Terraco’s U-value tables cover 50, 100, 150 and 200 mm boards. The values are indicative and vary with board density and specification, so your consultant should confirm the thickness needed for the project.
Fire safety
Terraco’s guidance is to use fire-retardant boards that comply with national regulations. In the UAE, facade systems must meet the UAE Fire and Life Safety Code, so confirm the specification with your consultant and Civil Defence before ordering. Where a higher fire rating is required, Terraco recommends its mineral wool system, EIFS Perma.
Guarantee and approvals
The system is covered by the Terraco International Guarantee when it is finished with a listed Terraco decorative coating and installed by an Approved Terraco EIFS Applicator. Terraco lists approvals for its EIFS range including EOTA ETAG 004, BBA, NSAI and UAE approvals.
Where to use it
- New villas, apartment buildings, schools and commercial buildings
- Renovating and insulating existing facades
- Projects targeting better energy performance under green building rules
Frequently asked questions
Alpha, Polar or Perma?
Alpha (EPS) is the general-purpose system. Polar (XPS) suits hot, humid climates with air-conditioned interiors and areas needing thinner, tougher insulation. Perma (mineral wool) is for a higher fire rating or breathable walls.
Can you quote a full system?
Yes. Send the elevations or wall area, required U-value and finish on WhatsApp, and we’ll put together the components with Terraco.
Alpha vs Polar vs Perma at a glance
| Alpha | Polar | Perma | |
|---|---|---|---|
| Insulation | EPS / graphite G-EPS | XPS | Mineral wool |
| Thermal conductivity | 0.033 / 0.030 W/(m·K) | 0.030 W/(m·K) | 0.040 W/(m·K) |
| U-value at 100 mm | 0.33 / 0.30 W/(m²·K) | 0.30 W/(m²·K) | 0.40 W/(m²·K) |
| Finishes | Terracoat, Terralite, Terol | Terracoat, Terralite, Terol | Breathable only: Terracoat Sil or Terol |
| Best for | General new build and renovation | Hot, humid, air-conditioned buildings | Higher fire rating, breathable walls |
Figures are from the Terraco EIFS brochure and are indicative.
EPS or graphite G-EPS?
Standard white EPS is the economical choice. Grey graphite-enhanced G-EPS insulates about 10% better according to Terraco, so you can reach the same U-value with a thinner board, which helps keep window reveals shallow. G-EPS boards absorb more heat from the sun before they are covered, so keep them shaded on site and get the basecoat on promptly.
Material quantities per m² (guide)
| Layer | Guide quantity |
|---|---|
| Styrofix adhesive | 4–5 kg/m² (spot or notched trowel) or 5–6 kg/m² (ribbon and dab) |
| Insulation board | 1 m² plus wastage; 600 × 1200 mm boards |
| Styrobond DP basecoat | 4–5 kg/m² at 3–5 mm |
| Terramesh | 1 m² plus overlaps and corner patches |
| Primer and finish | As per the chosen Terraco finish data sheet |
Quantities from the Terraco brochure and data sheets; confirm them for your project with us and Terraco.
Good practice on site
- Fix boards in a staggered bond with tight joints, and fill gaps with insulation, not adhesive.
- Add diagonal mesh patches at the corners of windows and doors to prevent cracking.
- Use reinforced mesh or extra basecoat on lower, impact-prone areas.
- Installation by an Approved Terraco EIFS Applicator is a condition of the Terraco International Guarantee.
Data sheets and related products
- Terraco EIFS brochure (PDF)
- EIFS Alpha product page
- Styrobond DP basecoat
- All Terraco products we supply
System details from the Terraco EIFS brochure. Always check the latest Terraco documentation before specifying.