Order welded steel fabric for a 300 m² villa ground slab or warehouse floor in Sharjah, Ajman, or Dubai by simply dividing 300 m² by 11.52 m² per sheet, and your steel fixers will run four sheets short right before the concrete pump arrives. Even worse, many site buyers get caught out by “commercial 6 mm mesh” sheets that actually use 5.2 mm wire at 220 mm spacing—failing the consultant’s caliper check against the specified BRC mesh sizes UAE structural drawings call for.
In the UAE, factory-welded steel fabric for concrete reinforcement is governed by GSO ISO 6935-3:2025 (Steel for the reinforcement of concrete — Part 3: Welded fabric), cold-reduced ribbed wire standard ISO 10544:2024, and BS 4483 / ASTM A1064/A1064M. Here is how to decode A98, A142, A193, A252, and A393 designations, verify the exact weight per 4.8 m × 2.4 m sheet on the weighbridge, and calculate your true sheet order including 300 mm side and end laps.
In This Guide
- Quick-Answer Cheat Sheet: UAE BRC Welded Wire Mesh Codes & Sizes
- BRC Welded Wire Mesh Weight Chart (BS 4483 & UAE Metric Sizes)
- Welded Fabric Mesh vs Tied 12 m Rebar Grids: Where to Use Each
- Worked UAE Quantity Calculation: 350 m² Villa Ground Floor Slab
- 5 Common BRC Mesh Mistakes on UAE Sites (And How to Avoid Them)
- Frequently Asked Questions (FAQs)
Quick-Answer Cheat Sheet: UAE BRC Welded Wire Mesh Codes & Sizes
- What “A142” or “A252” Means (BS 4483): The letter “A” stands for a Square Mesh (200 mm × 200 mm wire pitch) with identical wire diameters in both directions. The number (142, 193, 252, 393) is the cross-sectional steel area in mm² per metre width.
- Standard UAE Sheet Size: Full-spec structural BRC sheets measure 4.8 m × 2.4 m = 11.52 m² gross area per sheet (sized to fit horizontally inside standard UAE flatbed trucks).
- Effective Coverage After Laps (The 9.45 m² Rule): With a standard 300 mm (1.5-mesh-square) side and end overlap, each 4.8 m × 2.4 m sheet covers an effective net area of 4.5 m × 2.1 m = 9.45 m². Always divide your net slab area by 9.45 m² (not 11.52 m²) and add 5% cutting waste.
- Most Popular UAE Mesh Grades:
• A142 (6 mm @ 200×200 mm, 25.6 kg/sheet): Standard 100–125 mm villa ground slabs on grade & interlock sub-slabs.
• A193 (7 mm @ 200×200 mm, 34.8 kg/sheet): 125–150 mm car park slabs, villa garages, and ramp toppings.
• A252 (8 mm @ 200×200 mm, 45.5 kg/sheet): 150–175 mm industrial warehouse slabs and heavy loading bays.
• A393 (10 mm @ 200×200 mm, 71.0 kg/sheet): 200 mm+ logistics warehouse floors and structural raft toppings.
BRC Welded Wire Mesh Weight Chart (BS 4483 & UAE Metric Sizes)
In the UAE, consultants specify either British Standard BS 4483 codes (A98 to A393 at 200×200 mm pitch) or direct metric grids (such as 6 mm or 8 mm at 150×150 mm pitch) manufactured from 500 MPa cold-reduced ribbed wire under GSO ISO 6935-3:2025. Use the table below to verify delivery weights per square metre and per standard 4.8 m × 2.4 m (11.52 m²) sheet:
| Mesh Code / UAE Size | Wire Diameter (mm) | Mesh Pitch (Long. × Cross) | Steel Area (mm²/m) | Mass per m² (kg/m²) | Weight per 4.8×2.4 m Sheet | Sheets per Metric Tonne |
|---|---|---|---|---|---|---|
| A98 (BS 4483) | 5.0 mm | 200 × 200 mm | 98 mm²/m | 1.54 kg/m² | 17.74 kg | 56.4 sheets/t |
| A142 (BS 4483) | 6.0 mm | 200 × 200 mm | 142 mm²/m | 2.22 kg/m² | 25.57 kg | 39.1 sheets/t |
| UAE Metric 6@150 | 6.0 mm | 150 × 150 mm | 189 mm²/m | 2.96 kg/m² | 34.10 kg | 29.3 sheets/t |
| A193 (BS 4483) | 7.0 mm | 200 × 200 mm | 193 mm²/m | 3.02 kg/m² | 34.79 kg | 28.7 sheets/t |
| A252 (BS 4483) | 8.0 mm | 200 × 200 mm | 252 mm²/m | 3.95 kg/m² | 45.50 kg | 22.0 sheets/t |
| UAE Metric 8@150 | 8.0 mm | 150 × 150 mm | 335 mm²/m | 5.26 kg/m² | 60.60 kg | 16.5 sheets/t |
| A393 (BS 4483) | 10.0 mm | 200 × 200 mm | 393 mm²/m | 6.16 kg/m² | 70.96 kg | 14.1 sheets/t |
| UAE Metric 10@150 | 10.0 mm | 150 × 150 mm | 524 mm²/m | 8.22 kg/m² | 94.69 kg | 10.6 sheets/t |
Commercial & Weighbridge Warning: “Commercial 4×2 m Light Sheets” vs “Full BS 4483 4.8×2.4 m Sheets”
When comparing quotations in Sharjah, Ajman, or Dubai, watch out for uncertified “Commercial 6 mm Mesh” sold in smaller 4.0 m × 2.0 m (8.0 m²) or 3.6 m × 2.0 m sheets drawn from 4.8–5.2 mm wire (~11–13 kg per sheet). Those light sheets are fine for non-structural garden paths or floor screeds, but for an engineer-inspected ground floor slab, always specify full BS 4483 / GSO ISO 6935-3 4.8 m × 2.4 m sheets and verify the bundle weight on delivery.

Welded Fabric Mesh vs Tied 12 m Rebar Grids: Where to Use Each
When should a Quantity Surveyor or site engineer use prefabricated BRC welded wire mesh instead of cutting and tying individual 12 m BS 4449 B500B rebar bars on site?
- Speed & Labour Savings on Ground Slabs: Two steel fixers can lay, lap, and tie 350 m² of A142 or A252 welded mesh in half a shift, compared to 2 full days tying individual T8 or T10 bars at 200 mm centres. Because every intersection is factory electric-resistance welded under GSO ISO 6935-3, the grid cannot shift underfoot when concrete pump hoses are dragged across the bay.
- Crack Control in Toppings & Screeds: For 50–75 mm concrete screed toppings over hollow-core slabs, roof protection screeds, and stamped concrete villa courtyards, A98 or A142 mesh positioned in the upper third of the slab arrests drying shrinkage cracks far more effectively than widely spaced loose bars.
- When to Stick With Loose Deformed Rebar (Slab Rebar Calculator): Suspended structural slabs, transfer beams, pile caps, and heavily congested foundations requiring T12 to T25 bars with cranked bent-up bars and L-bars are faster and more economical to detail from 12 m rebar bundles than custom heavy mesh.
Worked UAE Quantity Calculation: 350 m² Villa Ground Floor Slab
Here is the exact step-by-step calculation to order A193 (7 mm @ 200×200 mm) BRC welded wire mesh sheets for a 350 m² villa ground slab before booking your concrete pour via our Concrete Volume Calculator:
Worked Example: 350 m² Villa Slab on Grade — Single Layer A193 Welded Mesh (4.8 m × 2.4 m Sheets)
Slab Parameters: Net slab plan area = 350.0 m² (25.0 m × 14.0 m, 150 mm thick C30 concrete). Specified reinforcement = Single top/mid-depth layer of BS 4483 A193 welded fabric (7 mm wire @ 200×200 mm pitch). Minimum required lap at all sheet edges = 300 mm.
- Step 1 — Gross vs Effective Area per Sheet:
• Gross sheet dimensions = 4.80 m × 2.40 m = 11.52 m² gross
• Deduct one 300 mm side lap and one 300 mm end lap per sheet: (4.80 m − 0.30 m) × (2.40 m − 0.30 m) = 4.50 m × 2.10 m = 9.45 m² effective net coverage per sheet. - Step 2 — Net Sheets Required: 350.0 m² ÷ 9.45 m²/sheet = 37.04 sheets net.
- Step 3 — Add 5% Off-Cut & Column Box-Out Wastage: 37.04 × 1.05 = 38.89 sheets → Order 39 sheets of A193 BRC Welded Wire Mesh (4.8 m × 2.4 m).
- Step 4 — Verify Total Steel Tonnage & Spacer Block Order:
• Total mesh weight = 39 sheets × 34.79 kg/sheet = 1,356.8 kg (1.36 metric tonnes).
• Concrete cover blocks (at 4 spacers per m² to prevent mesh sagging): 350 m² × 4 = 1,400 pcs of 50 mm Concrete Cover Blocks + 5 kg of Annealed GI Binding Wire to tie all 300 mm laps.
Commercial Note: Notice that 39 sheets equals 449.3 m² of gross mesh for a 350 m² slab—an effective 28.4% gross-to-net multiplier driven by the 300 mm lap rule. Always factor this 1.25–1.28 multiplier into your BOQ unit rate and check your total order value with our UAE 5% VAT Calculator.
5 Common BRC Mesh Mistakes on UAE Sites (And How to Avoid Them)
- Laying Mesh Flat on the Polythene Sheet and Trying to “Hook” It Up During Pouring: Never let labourers lay BRC mesh directly on the under-slab vapor barrier with the excuse that they will pull it up with a rebar hook while pouring concrete. Foot traffic and wet concrete weight push the mesh straight back to the bottom of the slab, leaving zero crack control at the top and puncturing the polythene sheet. Always seat the mesh on 40–50 mm concrete cover blocks or continuous steel bar chairs before inspection.
- Stacking 4 Layers of Mesh Corners at a Single 4-Way Intersection: Where four rectangular mesh sheets meet at a corner, overlapping all four sheets directly on top of each other builds up 8 layers of wire (e.g., 8 × 8 mm = 64 mm of solid steel thickness), stealing your top concrete cover and creating spalling cracks. Offset (stagger) adjacent rows of sheets like brickwork coursework so only 3 sheets meet at any junction.
- Lapping Sheets by Only 100 mm Instead of One Full Mesh Square (300 mm): Welded wire fabric transfers tension primarily through the welded cross-wires, not friction along smooth wire tails. Under BS 4483 and GSO ISO 6935-3, sheets must overlap by at least one full 200 mm pitch plus wire overhangs (minimum 300 mm to 400 mm) and be tied securely with binding wire every 400–600 mm.
- Forgetting to Cut Mesh Cleanly Across Contraction & Expansion Joints: If continuous A193 or A252 mesh runs uncut across a saw-cut contraction joint or an expansion joint board, the steel prevents the joint from opening and forces a jagged crack mid-bay. Stop or cut alternate/all mesh wires 50 mm short of movement joints as detailed on the structural drawings.
- Using Unsafe Un-Guarded Grinders Without PPE When Trimming Sheets Around Columns: Trimming springy 8 mm or 10 mm cold-drawn mesh wires around column starter bars or shuttering plywood box-outs can pinch cutting discs. Use heavy-duty bolt croppers for 5–7 mm wire, or fit a proper EN 12413 metal cutting disc on your angle grinder while wearing EN 166 safety goggles and cut-resistant gloves.

Frequently Asked Questions (FAQs)
What is the standard size of a BRC welded wire mesh sheet in the UAE?
The standard full-specification BRC welded wire mesh sheet size across Dubai, Sharjah, Ajman, and Abu Dhabi is 4.8 m long × 2.4 m wide (11.52 m² gross area per sheet). After deducting a mandatory 300 mm side and end overlap, one standard sheet provides 9.45 m² of effective net slab coverage. Lighter commercial screed mesh is also stocked in 4.0 m × 2.0 m (8.0 m²) sheets and rolls.
How much does an A142, A193, A252, and A393 mesh sheet weigh?
For a standard 4.8 m × 2.4 m (11.52 m²) sheet manufactured to BS 4483 / GSO ISO 6935-3: A98 (5 mm wire) weighs 17.74 kg (1.54 kg/m²); A142 (6 mm wire) weighs 25.57 kg (2.22 kg/m²); A193 (7 mm wire) weighs 34.79 kg (3.02 kg/m²); A252 (8 mm wire) weighs 45.50 kg (3.95 kg/m²); and A393 (10 mm wire) weighs 70.96 kg (6.16 kg/m²).
Where should BRC mesh be positioned inside a concrete ground floor slab?
When a single layer of BRC mesh is used primarily for drying shrinkage and thermal crack control in a slab on grade, it should be supported on chairs or cover blocks in the upper third of the slab depth (typically 40 mm to 50 mm below the top concrete surface). In thicker industrial slabs (175–250 mm), two layers of mesh (top and bottom, supported by steel chairs) are commonly specified.
What is the minimum overlap for BRC welded wire mesh in concrete slabs?
Under UAE structural specifications and BS 4483 / Eurocode 2 detailing rules, welded wire mesh sheets must overlap by at least one full mesh pitch plus overhangs—typically 300 mm to 400 mm minimum (or 35 to 40 times the wire diameter)—so that at least two welded cross-wires overlap at every side and end joint.
Need BRC Mesh Accessories, Binding Wire, Cover Blocks & Cutting Tools in the UAE?
Al Tashteb Al Saree Building Materials Trading (Bu Tina, Sharjah) supplies civil contractors across Sharjah, Ajman, and Dubai with annealed GI binding wire & site hardware, concrete cover blocks, polythene vapor barriers & curing compounds, bolt cutters, rebar hooks & hand tools, and angle grinders & metal cutting discs—all billed in AED incl. 5% VAT.